IntelliCon®Hydronic Heating Economizers
MODEL
CHW #1210
CHW Wi-Fi #1211
SYSTEM REQUIREMENTS
- Hydronic Boiler with non-proportional burner
- Input rating greater than 2.5 million BTU / hour
- Fueled by #2, #4 or #6 heating oil, natural gas or propane
- CHW can be used on boilers with an internal coil for domestic hot water
- Wi-Fi enabled CHW sends operational information and settings to your ‘smart’ phone, tablet or PC
TARGET FACILITIES
- Schools, Colleges & Universities
- Hotels and Resorts
- Large Catering Facilities
- Commercial Office Buildings
- Apartment Buildings,
- Garden Apartments
- Residential Cooperatives
- Governmental Buildings
- Other large scale heating systems
TYPICAL SAVINGS
Fuel savings range from 11% to 28% with some documented savings over 50%. The average realized savings for this control is 20.8% in the first year after installation.
XXMODEL
LCH #1220
SYSTEM REQUIREMENTS
- Hydronic Boiler with non-proportional burner
- Input rating between 400,000 and 2.5 million BTU / hour
- Fueled by #2, #4 or #6 heating oil, natural gas or propane LCH can be used on boilers with an internal coil for domestic hot water
TARGET FACILITIES
- Schools, Colleges & Universities
- Hotels and Resorts
- Catering Facilities
- Commercial Office Buildings
- Apartment Buildings
- Residential Cooperatives
- Restaurants
- Health clubs
- Governmental Buildings
- Other mid sized heating systems
TYPICAL SAVINGS
Fuel savings range from 11% to 38%. The average realized savings for this control is 17.7% in the first year after installation..
MODEL
HW+ #3250
SYSTEM REQUIREMENTS
- Hydronic Boiler with non-proportional burner
- Input rating less than 400,000 BTU / hour
- Fueled by #2 heating oil, natural gas or propane HW+ can be used on boilers with an internal DHW coil
TARGET FACILITIES
- Single family and small multi- family homes
- Apartment Buildings,
- Garden Apartments
- Residential Cooperatives
- Restaurants
- Health clubs
- Other small to mid-sized heating systems or DHW systems
TYPICAL SAVINGS
Fuel savings range from 10% to 22%. The average realized savings for this control is 14.3% in the first year after installation.
IntelliCon®Steam Heating Economizers
Model CHS #1110
& CHS Wi-Fi #1112
SYSTEM REQUIREMENTS
- Steam Heating Boiler with non- proportional burner
- Input rating greater than 5 million BTU / hour
- Burner must cycle off when set PSI is reached
- Boiler must maintain a minimum operating pressure of 5 psi
- Fueled by #2, #4 or #6 heating oil, natural gas or propane
- CHS can be used on boilers with an internal coil for domestic hot water
- Wi-Fi enabled CHS sends operational information and settings to your ‘smart’ phone, tablet or PC
TARGET FACILITIES
- Schools, Colleges & Universities
- Hotels and Resorts
- Large Catering Facilities
- Commercial Office Buildings
- Apartment Buildings,
- Garden Apartments
- Residential Cooperatives
- Health Care / Assisted Living
- Governmental Buildings
- Other large scale steam heating systems
TYPICAL SAVINGS
Fuel savings range from 12% to 23% with some documented savings over 50%. The average realized savings for this control is 19.0% in the first year after installation.
IntelliCon®Forced Air Heating Economizers
MODEL FA #3300
SYSTEM REQUIREMENT
- Warm air furnace with non-proportional burner
- Single stage burners and some two stage burners
- Input rating up to 400,000 BTU / hour
- Fueled by #2 heating oil, natural gas or propane
- Up-flow, counter-flow or horizontal discharge systems
- Unit heaters
TARGET FACILITIES
- Single & small multi-family homes
- Health Care facilities
- Restaurants
- Convenience Stores
- Shopping Malls
- Health clubs
- MFG and warehouses
- Other small to mid sized forced air heating systems
TYPICAL SAVINGS
Fuel savings range from 10% to 18%. The average realized savings for this control is 13.4% in the first year after installation.
IntelliCon®Cooling Economizers
MODEL AC #3400
SYSTEM REQUIREMENTS
- Package or split AC systems with compressors rated between 1.5 and 4 tons
- Reciprocating or scroll type compressors
- Hermetic or semi-hermetic style compressors
TARGET FACILITIES
- Single family homes and condos
- Small office buildings
- Hotels with PTAC units
TYPICAL SAVINGS
Electricity KWH savings range from 10% to 19%. The average realized savings for this control is 13.5% in the first year after installation.
MODEL AC #2400
SYSTEM REQUIREMENTS
- Commercial package or split AC systems with compressors rated 4 tons or larger
- Can be used on multi-stage systems
- Reciprocating or scroll type compressors Hermetic or semi-hermetic style compressors
TARGET FACILITIES
- Schools, Colleges & Universities
- Hotels and Resorts
- Convenience Stores
- Commercial Office Buildings
- Apartment Buildings
- Health Care / Assisted Living
- Family & Fast Food Restaurants
- Health clubs
- Governmental Buildings
TYPICAL SAVINGS
Electricity KWH savings range from 10% to 28%. The average realized savings for this control is 16.3% in the first year after installation.
MODEL PTAC #2600
SYSTEM REQUIREMENTS
- Package thru the wall systems with compressors rated between 1.5 and 4 tons
- Reciprocating or scroll type compressors
- Hermetic or semi-hermetic style compressors Compatible with heat pump
TARGET FACILITIES
- Single family homes and condos
- Small office buildings
- Hotels with PTAC units
- Assisted living facilities
TYPICAL SAVINGS
Electricity KWH savings range from 10% to 19%. The average realized savings for this control is 13.5% in the first year after installatio
MODEL RU#2500
SYSTEM REQUIREMENTS
- Commercial refrigeration systems with compressors rated 1.5 HP or larger
- Reciprocating or scroll type compressors
- Hermetic or semi-hermetic style compressors
TARGET FACILITIES
- Cafeterias
- Refrigerated Warehouses
- Convenience Stores
- Restaurants / Catering
- Mid-sized to large food / produce storage facilities
- Small Food stores with glass door and open front display cases
TYPICAL SAVINGS
Electricity KWH savings range from 10% to 28%. The average realized savings for this control is 16.3% in the first year after installation.